DISPOLE


| Step 1 |
Transfer Unit |
| Step 2 |
Cooling Stage |
| Step 3 |
Ionizer |
| Step 4 |
Pick & Place Unit |
| Step 5 |
Placement of Disc Separator |
| Step 6 |
Stock Stage |
- Compact High performance - This system provides disc cooling just after moulding, anti static treatment and stacking to a stacking spindle.
- Disc spacer loading - Spacers are placed between discs to prevent 2 discs from sticking together and promote heat radiation.
- Cycle time - The system can perform at 3.5-seconds-per-cycle.
| Power Source |
AC200V (50/60Hz) |
| Power Consumption |
10A at AC200V |
| Air Consumption |
150 Litre (Normal) /min Max (3 Vacuum Circuits) |
| Cycle Time |
3.5 sec min |
| Cooling Station |
12 positions |
| Number of Stacking Spindles |
6 |
| Clean Room Rating |
Class100 |
| Net Weight |
400Kg |
|
Drive Part |
Drive Source |
Drive Stroke |
| Transfer Unit |
rotation |
Pneumatic cylinder |
approximately 180 degrees rotation |
| Cooling Stage |
rotation |
DD motor |
12 division |
| Pick & Place Unit |
swing
up/down |
Pneumatic cylinder
Pneumatic cylinder |
90 deg. swing
approximately 20mm stroke. |
| Stack Stage |
rotation |
Induction Motor |
6 division |
| Spacer Stage |
rotation |
Induction Motor |
6 division |
| Stack Stage Side Lifter |
up/down |
Induction Motor |
approximately 270mm stroke. |
| Spacer Stage Side Lifter |
up/down |
Induction Motor |
approximately 270mm stroke. |
|